Choosing the Right Septic Tank: Factors to Consider for Your Property

Graeme Blakey - 15th August 2024

Originally published: 15th August 2024  |  Last updated: 4th September 2026

Choosing an off-mains sewage system is not simply a matter of buying the biggest septic tank that will fit in the garden. In England, the correct choice depends on whether a connection to the public foul sewer is reasonable, where the treated effluent will discharge, how much sewage the property will produce, whether the ground is suitable for a drainage field, the site’s environmental constraints and the maintenance you are prepared to carry out.

At DGS Limited, we install septic tanks and sewage treatment plants across the North East. We look at the whole system—tank or treatment unit, inlet and outlet drainage, ground conditions, drainage field, access for emptying, levels and the practical route for installation—rather than treating the tank as a standalone product. You can read more about our septic tank and sewage treatment plant installations.

Important 2026 Rule: A Septic Tank Must Not Discharge Directly to a Watercourse

For properties in England, the Environment Agency’s general binding rules state that a septic tank discharging to ground must use an infiltration system or drainage field. If the discharge is to a surface water such as a river or stream, the sewage must be treated by a small sewage treatment plant instead. A septic tank outlet running directly to a ditch, stream or other watercourse is therefore not a compliant “new septic tank” option under the general binding rules.

First Decide Whether a Septic Tank Is the Right Type of System

People often use “septic tank” as a general term for any private sewage system, but the Environment Agency distinguishes between septic tanks, small sewage treatment plants and cesspools. The choice affects discharge options, power requirements, maintenance and legal obligations.

Septic tank, sewage treatment plant or cesspool?
SystemHow it worksWhere the contents goKey practical point
Septic tankSolids settle and wastewater leaves the tank for further treatment in the ground.Under the general binding rules, effluent goes to ground through a compliant drainage field/infiltration system.Simple and passive, but only suitable where the site and ground can support a proper drainage field.
Small sewage treatment plantUses mechanical/electrical treatment to produce a higher-quality effluent than a septic tank.Can discharge to a compliant drainage field or, where all rules are met, to flowing surface water.Needs power, servicing and maintenance but gives more discharge flexibility.
CesspoolSealed holding tank with no discharge.All sewage is stored until removed by tanker.Requires frequent emptying; the general binding rules for discharges do not apply because there is no discharge.

Can You Connect to a Public Foul Sewer Instead?

Before selecting a new private treatment system, connection to the public foul sewer must be considered. For discharges that started on or after 1st January 2015, the Environment Agency’s general binding rules say a single domestic property cannot meet those rules if there is a public foul sewer within 30 metres of any boundary of the premises served. The rules become more complex for developments serving more than one property or non-domestic premises.

This does not mean every site within 30 metres can automatically be connected without engineering or legal work. It means the public sewer question has to be resolved before a new private discharge is treated as the default solution. We can help with the physical drainage and groundworks assessment, while the sewerage company, local authority and other relevant bodies deal with the permissions and connection requirements within their remit.

How Much Capacity Does the System Need?

Capacity should be based on the maximum sewage load the system is expected to receive, not simply the current number of occupants on the day the tank is ordered. The Environment Agency requires a treatment system to have enough capacity for the maximum sewage it needs to treat and directs installers to British Water’s Flows and Loads sizing guidance for systems installed after 1st February 2006.

British Water’s guidance provides loading values for different types of premises so designers can calculate daily hydraulic and organic load. For houses, sizing should account for the property’s potential occupancy rather than relying on a short-term low-use pattern. Commercial, hospitality and other non-domestic premises need different loading assumptions because wastewater strength and daily peaks can be very different.

2,000 L/dayThe general binding-rule maximum for an exempt small sewage discharge to ground is 2 cubic metres per day.
30 mFor a single domestic property, qualifying post-2015 discharges cannot meet the general binding rules if a public foul sewer is within 30 metres of any boundary served.
50 mA discharge to ground must not be within 50 metres of a well, spring or borehole used for domestic or food-production water supply.

Those numbers are regulatory thresholds, not a universal tank-size formula. A tank has to be sized for the property and the treatment process, and the drainage field must also be designed for the site.

The Drainage Field Is Just as Important as the Tank

A septic tank does not fully treat sewage by itself. It separates solids and allows partially clarified effluent to leave the tank; the soil within a properly designed drainage field provides further treatment. That means a site with no suitable area for infiltration may not be suitable for a septic tank even if there is plenty of physical room for the tank vessel.

Approved Document H and the Environment Agency rules require appropriate drainage-field design. Ground permeability, groundwater conditions, flood risk, available area, gradients, nearby water supplies and environmental designations can all affect whether a ground discharge is acceptable.

Questions We Need to Answer Before Choosing the System

  • Is a public sewer connection reasonable?
  • What type of discharge is proposed? Ground through a drainage field or surface water from a treatment plant?
  • What is the maximum design population and wastewater load?
  • Can the ground accept effluent at a suitable rate?
  • Is there enough land for a correctly designed drainage field?
  • Is the proposed discharge in a restricted groundwater or environmentally sensitive location?
  • Can a tanker reach the system safely for desludging?
  • Can the installation be excavated and backfilled without undermining buildings, roads or utilities?
  • Does the customer prefer a passive septic tank or a powered treatment plant with higher treatment performance?
  • What future changes could increase the load? Extensions, extra bedrooms, holiday lets or commercial use can all matter.

Percolation and Ground Conditions

A drainage field has to be matched to the soil. If the ground is too impermeable, effluent may not disperse adequately. If it is too freely draining or the groundwater situation is unsuitable, there can be pollution risk. Site testing and design therefore matter more than choosing a tank by catalogue capacity alone.

The Environment Agency’s guidance was updated on 23rd July 2026 to address engineered ground used to reduce percolation rate. It confirms that such arrangements can only meet the general binding rules in specified circumstances, including a minimum percolation value and compliance with the other recommendations of BS 6297:2007. This is a specialist design issue rather than a general DIY solution for unsuitable land.

Groundwater and Drinking-Water Protection

The general binding rules do not allow a discharge to ground in groundwater source protection zone 1 or within 50 metres of a well, spring or borehole used to supply water for domestic or food-production purposes. Newer discharges also have restrictions around designated environmental sites.

These restrictions are one reason we do not recommend ordering a septic tank before the discharge route and site constraints have been checked. The right tank in the wrong location is still the wrong system.

Septic Tank Materials: What Matters More Than the Label?

Modern septic tanks and treatment plants are commonly manufactured from materials such as glass-reinforced plastic or polyethylene, while older systems may be concrete, brick or other construction. Material affects handling, structural strength, installation method and resistance to ground conditions, but we do not choose purely on “plastic versus concrete”.

For a new system, the Environment Agency requires compliance with the relevant British Standard that applied when the system was installed. Its current guidance identifies BS EN 12566 for septic tanks and small sewage treatment plants and BS 6297:2007 for drainage fields. Installation must also follow the manufacturer’s specification, including requirements for excavation, base, backfill, groundwater conditions and anchoring where applicable.

Septic Tank vs Sewage Treatment Plant: Which Is Better?

Neither is automatically better. A septic tank has no treatment motor or aeration system and can be simple to operate, but it relies on a compliant drainage field and cannot discharge directly to surface water. A sewage treatment plant treats the wastewater to a higher standard and can offer more discharge options, but it requires power and regular servicing and has mechanical components that need maintenance.

For a rural property with suitable ground and enough land, a septic tank and drainage field may be appropriate. Where ground conditions, space or discharge requirements make that unsuitable, a treatment plant may be the correct route. The decision should follow site assessment and regulation, not marketing claims.

Practical comparison when choosing an off-mains system
FactorSeptic tankSewage treatment plant
ElectricityNormally no power required for the treatment process.Usually requires continuous or regular electrical operation.
Effluent qualityPrimary settlement only; further treatment occurs in the drainage field.Higher treatment level before discharge.
Surface-water dischargeDirect discharge to watercourse is not allowed under the general binding rules.May discharge to qualifying flowing surface water if all relevant rules are met.
Ground requirementNeeds a suitable compliant drainage field.Can also use a drainage field; surface-water option may be possible in qualifying cases.
ServicingRequires regular desludging and inspection.Requires desludging plus mechanical/electrical servicing to manufacturer requirements.
Best useSites with suitable ground, space and compliant ground discharge.Sites needing higher treatment or where a compliant surface-water discharge is necessary.

How Often Does a Septic Tank Need Emptying?

The Environment Agency says sludge must be removed before it exceeds the system’s maximum capacity and advises desludging at least once a year or in line with the manufacturer’s instructions. The actual requirement depends on tank size, occupancy, usage and system design.

Allowing sludge to carry over into the drainage field can cause damage and pollution and may lead to expensive remedial work. The waste carrier used to remove sludge must be registered. When we plan an installation, tanker access is therefore part of the site layout—not something to think about after the garden has been finished.

Building Regulations and Planning

Environment Agency guidance states that a new septic tank or small sewage treatment plant must have building-regulations approval and may also need planning permission. Approved Document H contains the statutory guidance for foul-water drainage and disposal in England.

Environmental permitting is separate. If the discharge meets all applicable general binding rules, a permit is not normally needed; if those rules cannot be met, an environmental permit may be required. The Environment Agency will not generally issue a permit simply to avoid a reasonable public sewer connection.

England Rules Apply to This DGS Guide

DGS Limited operates in the North East of England, so this article uses the Environment Agency rules for England. Scotland, Wales and Northern Ireland have different regulators and requirements. If the property is outside England, use the rules for that jurisdiction rather than applying this guide unchanged.

What About Flood Risk?

A tank or drainage field should not be selected in isolation from site levels and flood conditions. Flooding can affect access, drainage-field performance and the risk of pollution. Some discharge arrangements specifically cannot meet general binding rules in floodplains. Site design must consider where water will go in wet conditions, not just whether the system appears to work in summer.

Installation Access and Groundworks

Even when the treatment specification is correct, the project can fail if the installation route has not been planned. Tanks are large, excavations can be deep and safe access is needed for plant, materials and future maintenance. Existing utilities, retaining walls, buildings, roads, trees and finished landscaping all affect the method.

Our drainage and groundworks capability allows us to consider excavation, pipe levels, bases, backfill, drainage connections and reinstatement as one project rather than leaving the tank installation disconnected from the rest of the site.

How We Select a System at DGS Limited

1. Confirm the property and proposed use

We establish whether the site is domestic, commercial, holiday accommodation or another use and estimate the maximum design load.

2. Check the discharge route and sewer context

We establish whether public sewer connection needs to be considered and whether the proposed private discharge is to ground or, for a treatment plant, potentially to surface water.

3. Assess site and ground constraints

We consider drainage-field space, ground conditions, levels, water protection, access, flood risk and the physical installation area.

4. Size the system correctly

We use the design population and loading rather than choosing a vessel by price alone.

5. Compare whole-life requirements

We explain power, servicing, desludging, access and maintenance so the customer understands how the system will need to be operated after installation.

6. Install to the approved design and manufacturer requirements

The vessel, pipework, drainage field and groundworks all need to work together. A compliant product can still fail if installed in unsuitable conditions or contrary to its specification.

If You Are Buying a Property with an Existing System

The Environment Agency requires the seller to tell the new operator in writing that a sewage discharge exists and to provide information about the treatment and drainage system, its main locations, changes, maintenance requirements and available maintenance records. That information should form part of your due diligence.

Do not assume an existing tank is compliant because it has “always been there”. Establish whether it is a septic tank, treatment plant or cesspool, where it discharges, whether the discharge meets the relevant rules and whether the drainage field is functioning. If a septic tank discharges directly to a watercourse, the system needs to be brought into compliance.

Our Checklist Before You Order a Septic Tank

  • Confirm whether a public foul sewer connection must be considered.
  • Identify the proposed discharge point and whether it is to ground or surface water.
  • Check environmental and groundwater restrictions.
  • Calculate design population and sewage load using appropriate sizing guidance.
  • Confirm ground suitability and drainage-field area.
  • Check planning and building-control requirements.
  • Choose a product compliant with the applicable standard.
  • Plan safe excavation, delivery, backfill and future tanker access.
  • Budget for annual desludging and, for treatment plants, servicing and electricity.
  • Keep installation, maintenance and emptying records for future owners.

Need Help Choosing an Off-Mains Sewage System?

We can assess the site, explain whether a septic tank or sewage treatment plant is appropriate, and plan the drainage and groundworks needed for installation across the North East.

Contact DGS Limited or call 0191 300 3084 to discuss your property.

Frequently Asked Questions About Choosing the Right Septic Tank

Current answers about septic tanks, treatment plants, drainage fields, capacity, the 30-metre sewer rule, discharge limits, planning, emptying and 2026 Environment Agency requirements.


A septic tank primarily separates solids from liquid and relies on a drainage field for further treatment in the ground. A small sewage treatment plant uses mechanical/electrical processes to treat wastewater to a higher standard before discharge.

No, not under the Environment Agency's general binding rules in England. A septic tank must discharge to ground through a compliant drainage field. A qualifying discharge to flowing surface water must come from a small sewage treatment plant.

Size the system for the maximum expected sewage load, not just current occupancy. Environment Agency guidance directs installers to British Water's Flows and Loads sizing criteria for systems installed after 1 February 2006. Property type and design population both matter.

Under the general binding rules, a small sewage discharge to ground can be up to 2 cubic metres, or 2,000 litres, per day. That is a regulatory discharge threshold, not a recommendation that every tank should have a 2,000-litre capacity.

For a single domestic property with a discharge started on or after 1 January 2015, the general binding rules cannot be met if a public foul sewer is within 30 metres of any boundary of the premises served. Multi-property and non-domestic calculations differ.

Yes, for a compliant discharge to ground under the general binding rules. The drainage field is an essential part of the treatment process because the soil provides further treatment after wastewater leaves the septic tank.

No. A foul-water drainage field is a specifically designed infiltration system for treated septic effluent. It is not the same as a simple rainwater soakaway or a deep point discharge. The design must meet the relevant wastewater rules and standards.

The Environment Agency says sludge must be removed before it exceeds the system's maximum capacity and advises at least annual desludging or the frequency stated by the manufacturer. Higher occupancy or a smaller tank may require more frequent emptying.

A conventional septic tank normally relies on gravity and settlement and does not need electricity for the treatment process. A small sewage treatment plant normally has powered mechanical components such as aeration or pumps and therefore has different running and servicing requirements.

You must have building-regulations approval for a new septic tank or small sewage treatment plant in England, and planning permission may also be needed. Check the site-specific requirements with the local planning and building-control authorities before installation.

Current Environment Agency guidance identifies BS EN 12566 for septic tanks and small sewage treatment plants and BS 6297:2007 for drainage fields. The system must meet the relevant standard in force when it is installed and the manufacturer's installation specification.

The general binding rules do not allow a discharge to ground within 50 metres of a well, spring or borehole used to supply water for domestic or food-production purposes, and discharges are also restricted in groundwater source protection zone 1.

A conventional septic tank may not be suitable. Depending on the site, a different treatment/discharge solution, connection to a public sewer or an environmental permit may need to be considered. Do not try to solve unsuitable ground simply by installing a larger tank.

Environment Agency guidance requires the new operator to be told in writing about the sewage discharge and to receive a description and location of the system, details of changes, maintenance requirements and available maintenance records.

Yes. We install septic tanks and sewage treatment plants and can deal with the associated drainage and groundworks. We first assess the site and discharge requirements so the selected system is appropriate for the property rather than recommending one type in every case.

Sources and References

The regulatory, sizing, drainage-field and maintenance statements in this article were checked against the following independent external sources for England. DGS-specific service statements are based on our own operations and are not listed as external evidence.

  • Environment Agency / GOV.UK — “General binding rules: small sewage discharge to the ground”, last updated 23 July 2026. Used for current England rules on septic-tank discharges to ground, drainage fields, discharge volume, public sewer proximity, groundwater protection, British Standards, capacity, annual desludging, waste carriers, seller information and building-regulations approval.
  • Environment Agency / GOV.UK — “General binding rules: small sewage discharge to a surface water”. Used for the rule that a surface-water discharge must be from a small sewage treatment plant, not directly from a septic tank, and for current surface-water discharge requirements.
  • Environment Agency and Defra / GOV.UK — “General binding rules for small sewage discharges with effect from 2 October 2023”. Used for the statutory general binding-rule thresholds and additional rules for discharges started on or after 1 January 2015 and new discharges started on or after 2 October 2023.
  • Ministry of Housing, Communities and Local Government / GOV.UK — “Drainage and waste disposal: Approved Document H”. Used for statutory guidance on foul-water drainage and disposal, including private wastewater systems and drainage-field design in England.
  • British Water — “Flows and Loads – Sizing Criteria, Treatment Capacity for Sewage Treatment Systems”. Used for the principle that off-mains treatment systems should be sized from calculated hydraulic/organic loading and property use rather than a one-size-fits-all tank capacity.
  • Environment Agency / GOV.UK — “Septic tanks and sewage treatment plants: what you need to do”. Used for the distinction between septic tanks and small sewage treatment plants and the requirement to meet the applicable general binding rules or obtain a permit where required.
  • Environment Agency / GOV.UK — “Your property has a cesspool”. Used for the distinction between a sealed cesspool and a discharging treatment system and the maintenance principle that a cesspool must not leak or overflow.